Look up your code or browse by brand. You read what it means and what you can try yourself. If that does not work, book the breakdown service from € 149.

An error code is a clue, not a diagnosis. The same code can be a dirty filter, but also a faulty sensor. That is why each code says what you can safely do yourself. Never open the unit yourself.

First check these three things: is the plug in, is the circuit on in the meter cupboard, and is the filter clean.

Find your error code

The brand and type are on the unit itself.
Type what is shown on the screen.

Or browse by brand

Duco
Duco DucoBox Energy
CodeMeaning
Geen codeThe DucoBox Energy has power but does not respond. The circuit board has to be checked or replaced.
1.4.1No response from the extract fan. Check the fan and replace it if needed.
28.4.1No response from the supply fan. Check the fan and replace it if needed.
3.1.xTemperature sensor ODA (outdoor air entering the unit).
4.1.xTemperature sensor ETA (extract air from the home to the unit).
6.1.xTemperature sensor EHA (exhaust air from the unit to outside).
30.1.xTemperature sensor SUP (supply air from the unit to the home).
35.17.xA temperature sensor with a value that is too low or too high, or that cannot be read.
16.1.xPressure sensor of the extract.
29.1.xPressure sensor of the supply.
31.19.1Warning: replace the filters.
32.10.1Warning: the outdoor temperature is too low. The ventilation is off for 8 hours.
33.10.1The outdoor temperature is too low. The ventilation is off permanently. Restart the DucoBox later.
36.24.1The connection to the weather station is lost. Check the connection.
36.24.2The connection to the outdoor temperature sensor is lost. Check the connection.
37.17.xCO₂ sensor in the control or room sensor with a value that is too low or too high, or that cannot be read.
40.17.xHumidity sensor in the control or room sensor with a value that is too low or too high, or that cannot be read.
42.22.1The number of connected valves is too high.
42.22.2The number of connected valves is too low. The minimum is 2.
43.23.1Warning: the balancing has not been done yet or failed. Balance again.
43.23.2Warning: the desired airflow is not reached. Check the whole installation.
44.6.1There is no connection to the Duco Pre-Heater. Check the connection.
44.6.2A Duco Pre-Heater is connected. Set it up in the settings.

How to read the list: on the DucoBox Energy choose INFO and then FOUTENLIJST (error list). Other units are read out with the Duco Installation App or the Duco Network Tool. The x at the end of a code stands for the kind of deviation: 1 too low, 2 too high, 3 cannot be read, 4 has measured the same value for a long time, 5 short-circuited and 6 poor connection. Replacing sensors, fans and circuit boards is a job for a technician. Source: Duco service instructions error codes L2004550, revision B (06.05.2024).

Brink
Brink Renovent Excellent 300 and 400
CodeMeaning
E100, E101Pressure sensor or its hoses. A technician has to check this.
E103Bypass. A technician has to check this.
E104Extract fan.
E105Supply fan.
E106, E107, E108A temperature sensor (outdoor, extract or external).
E109, E111CO₂ sensor or humidity sensor.
E999The dip switches in the unit are set wrongly.
FILTERClean or replace the filters and reset with the R button.

With a locked fault the fans are off. You cannot clear it yourself. Source: the manual of the Brink Renovent Excellent 300/400, chapter 8.

Brink Flair
Error code / subcodeMeaning
E190 / E1000Self-test not passed. No action needed.
E152 / E1001Flash memory faulty. The unit stops if possible. The UWA2-B base board has to be replaced.
E153 / E1002EEPROM memory faulty. The unit goes to the factory setting and ventilation setting 2. The UWA2-B base board has to be replaced.
E105 / E1011The requested supply airflow is not reached. The unit keeps running. Clean or replace the filters and check that the ducts are not blocked.
E104 / E1012The requested extract airflow is not reached. The unit keeps running. Clean or replace the filters and check that the ducts are not blocked.
E000 / E1013The outdoor air temperature is too high. The unit goes to standby. In warm weather with a supply under the roof tiles: wait until the air has cooled or have a roof terminal installed. In cold weather or with another supply: a technician replaces the temperature sensor (NTC).
E105 / E1100Supply fan faulty. The unit goes to standby. The fan has to be replaced. The message clears by itself when the unit is powered again.
E104 / E1120Extract fan faulty. The unit goes to standby. The fan has to be replaced. The message clears by itself when the unit is powered again.
E103 / E1200Bypass faulty. Check the wiring. Replace the bypass or the wiring harness.
E106 / E1300Sensor NTC1 faulty. The unit goes to standby. Check the wiring. Replace the sensor or the wiring.
E107Sensor NTC2 faulty (only on types 450 and 600). The unit goes to standby. Check the wiring. Replace the sensor or the wiring.
E111 / E1400RHT sensor 1 faulty. There is no humidity control. Check the wiring. Replace the sensor or the wiring.
E114 / E1500Setting switch faulty. The unit goes to setting 1. The switch has to be replaced.
E113 / E1600Internal preheater faulty. The frost protection goes to imbalance mode. Check the fuses and the wiring. Replace the wiring if it is damaged, otherwise the preheater.
E130 / E1800Relay output 1 faulty. The output signal is not available. Disconnect the power and replace the UWA2-B board.
E115 / E2000General message, only visible with the service tool. Check the wiring and replace damaged wiring. If the fault stays, the UWA2-B has to be replaced.
E120 / E2100eBus fault. Brink Air Control and other accessories on the eBus do not work. The unit itself works. Check the cabling and the accessories. If the fault stays, the UWA2-B base board has to be replaced.
E121 / E2200Fault on the internal bus. Brink Air Control and other accessories do not work. The unit itself works. Check the cabling and the accessories. If the fault stays, the UWA2-B base board has to be replaced.
E122 / E2300Internal ModBus fault. The unit goes to standby. Check the wiring and the connections on the UWA2-B and the fans. Replace a damaged wiring harness, then the UWA2-B and the fans if needed.
E123 / E2400External ModBus fault. Control via ModBus does not work. Check the cabling and the accessories. If the fault stays, the UWA2-B base board has to be replaced.
E124 / E2500USB port faulty. The USB interface cannot be used. Replace the USB accessory. If the fault stays, the UWA2-B base board has to be replaced.

Write down the error code and, if you can see it, the subcode. What you can most often do yourself: clean or replace the filters and check that the ducts are clear. The rest is a job for a technician. Source: Brink Flair 300 installation manual.

Itho Daalderop
Itho Daalderop HRU ECO
CodeMeaning
W01Warning: both filters are dirty. Clean them with a vacuum cleaner. You can turn them 180° and use them once more.
W02Warning: the filters have reached the end of their life. Replace both filters.
B01Blockage. Restart the unit. If the message comes back, call the installer.
E01Lock-out, for example a faulty fan. Restart the unit. If the message comes back, call the installer.
H01, H02Internal fault, such as communication with the control or the clock. Restart the unit. If the message comes back, call the installer.

The screen shows four kinds of messages: warning (W), blockage (B), lock-out (E) and internal fault (H). If a light flashes red and the code is not listed, it is a job for the installer. On an HRU ECO 300, W flashes slowly blue, B slowly red, E quickly red and H is solid red. You clear the filter message in the filter menu, or by holding the up or down arrow for 3 seconds.

Itho HRU ECO: no code, but a complaint
ComplaintWhat you can do
Poor air quality, or at times no supply or extractClean or replace dirty filters. Clean the valves. Have the ducts cleaned if they are dirty.
Unit does not respond to the switchFrost protection active? Then it is not a fault: wait until it gets warmer outside. Otherwise: pair the switch again, check that the battery is in and not empty, and keep the distance to the unit small. A switch of another brand does not work. If nothing helps, the switch is faulty.
Unit does not respond to the CO₂ or humidity sensorIs the system on Auto? Does the sensor have power (plug or batteries)? Is the sensor paired, close enough and of the same brand? If not, replace it.
The fan has stoppedIs the plug in the socket and is there power? Try another socket.
Cold air in the homeThe filter in the extract is blocked. Clean or replace it.
Fan suddenly runs faster or slowerUsually not a fault: the timer has ended, the unit reacts to CO₂ or humidity, or after 24 hours on setting 1 or 3 it returns to Auto. Is a switch of the neighbours paired to your unit? Then unpair all switches and pair all switches and sensors again.

Source: Itho Daalderop HRU ECO user manual, faults chapter.

Itho Daalderop HRU 375
Itho Daalderop HRU 375: warnings
NumberMeaning
1Filter dirty (volume measurement). Disconnect the power, replace the filters and then reset the filter warning.
2Filter dirty (time measurement). Disconnect the power, replace the filters and then reset the filter warning.
3Extract flow warning: the extract fan does not reach the desired airflow within 10 seconds. Clean the ducts, especially the extract, and then check the airflow.
4Supply flow warning: the supply fan does not reach the desired airflow within 10 seconds. Clean the ducts, especially the supply, and then check the airflow.

With a warning the unit keeps running. The light on the unit flashes orange when a filter is dirty. A flow warning only shows in the app or on the thermostat.

Itho Daalderop HRU 375: blockages
NumberMeaning
11Fault in the internal humidity sensor. The ventilation goes to Auto. The electronics compartment or the internal humidity sensor has to be replaced.
12Fault in the extract humidity sensor. The ventilation goes to Auto. The fan module has to be replaced.
13Fault in the supply humidity sensor. The ventilation goes to the highest setting. The fan module has to be replaced.
14Fault in the internal temperature sensor. The ventilation goes to Auto, the frost damper and bypass damper close and the controls are blocked. The electronics compartment has to be replaced.
15, 16Fault in the extract (15) or supply (16) temperature sensor. The ventilation goes to the highest setting, the frost damper and bypass damper close and the controls are blocked. The fan module has to be replaced.
17, 18, 19, 20Fault in the damper of zone 1, 2, 3 or 4. The unit works normally, but the airflow may be out of balance. The damper is not connected properly or is faulty.
21, 22Fault in the bypass damper (21) or frost damper (22). The unit works normally, but the airflow may be out of balance. The damper is not connected properly or is faulty.
23Fault in the electronics compartment. The ventilation goes to Auto. The compartment has to be reconnected or replaced, followed by a new commissioning.

With a blockage both lights on the unit flash red and the unit works differently than normal. The message disappears by itself once the cause is solved. Always disconnect the power first.

Itho Daalderop HRU 375: lock-outs
NumberMeaning
31, 32Fault in the extract (31) or supply (32) volume sensor. The unit stops. The fan module has to be replaced.
33, 34Fault in the extract (33) or supply (34) fan module. The unit stops. The fan module has to be replaced.

With a lock-out the unit is off and both lights flash red. After repair the message disappears on restart. A technician is needed for all blockages and lock-outs. You see the numbers in the app and on the Spider climate thermostat. Source: Itho Daalderop HRU 375 user manual, Faults chapter.

Zehnder
Zehnder ComfoAir Q
MessageMeaning
FILTERS NU WISSELENThe internal filters must be replaced now.
FILTERWISSEL VERWACHTThe internal filters need replacing soon. Order new ones already.
EXTERNE FILTER ALARMThe external filter must be replaced or cleaned. Then reset the errors.
GELUIDSBEPERKINGNot a defect. The unit meets too much resistance and may therefore make more noise. Usually valves are too far closed, a fire damper is closed, a butterfly valve sticks or is fitted the wrong way round, or the filters are extremely dirty.
EXT_PRESSURE_EHA, EXT_PRESSURE_SUPNot a defect. Too much resistance, so the desired airflow is not reached. EHA points to resistance on the extract side, SUP on the supply side. The causes are the same as for noise limitation.
AIRFLOW_EHA, AIRFLOW_SUPThe extract or supply airflow does not reach the set value. Check whether valves or grilles are blocked and have the ducts inspected.
FAN_EHA, FAN_SUPFault in the extract or supply fan. A technician has to check the fan and the connections on the control board.
PRESSURE_EHA, PRESSURE_SUPFault in the pressure sensor of the extract or supply. First check whether valves or grilles are blocked. After that a technician is needed.
SENSOR_EHA, SENSOR_SUPFault in the extract or supply sensor. A technician has to check this.
SENSOR_ETA, SENSOR_ODA (ODA-error)The top sensor on the outside is faulty. Zehnder replaces this sensor free of charge. The request goes through the installer in the Zehnder portal. An installer submits this.
TEMP_SENSOR_EHA, TEMP_SENSOR_SUP, TEMP_SENSOR_ETA, TEMP_SENSOR_ODAA temperature sensor reports a deviating temperature. A technician has to check the sensor and the connections.
HUMID_EHA, HUMID_SUP, HUMID_ETA, HUMID_ODAA humidity sensor reports a deviating humidity. A technician has to check the sensor.
TEMPCONTROL_SUPFault in the spindle motors of the modulating bypass.
DANGER! OVERHEATING!Two or more sensors measure a wrong temperature. Have a technician come, so that he also checks for lasting damage.
FROST ERRORThe supply air temperature is too low. Wait until it is at least -7 °C outside.
PREHEAT ERRORFault in the preheater.
PREHEAT_LOCATION ERRORThe preheater is not in the right place. Check whether the unit meets a lot of resistance: filters, valves, fire dampers and butterfly valves.
PREHEAT_PRES ERRORNo communication between the preheater and the unit.
GROUND_HEAT_CONNECT, POSTHEAT_CONNECTNo communication between the unit and the ComfoFond-L Q or the post-heater.
GROUND_HEAT_TEMP, POSTHEAT_TEMPThe temperature sensor of the ComfoFond-L Q or the post-heater reports a deviating temperature.
OPTION_BOX CONNECT ERRORNo communication between the option box and the unit. Do you not have an option box? Then clear the message in the installer menu: MENU, INSTELL. INSTALLATEUR, RESET, FOUTEN RANDAPP., and choose RESET ANALYSE and then RESET FOUTEN.
INIT ERRORThe unit has not been commissioned. A technician does that with the commissioning assistant.
SERVICE MODUSThe basic functions of the unit are switched off. This only belongs during maintenance. If no technician is working, the service mode has to be stopped.

How to read out the messages:

  1. Choose RESET FOUT (reset fault) and confirm.
  2. Wait 5 minutes.
  3. Go to STATUS, HUIDIGE FOUTEN (current faults) and note the codes.
  4. Go to TOESTEL, TOESTELTYPE (unit type) and note the type.

Send the codes and type via WhatsApp, so we know what is needed.

EHA stands for the exhaust to outside, SUP for the supply to the home, ETA for the extract from the home and ODA for the outdoor air. Source: ComfoAir Q error codes from Zehnder Netherlands.

Zehnder ComfoAir E 300 and E 400
MessageMeaning
FILTER ALARMThe internal filters are dirty. Replace them now.
FILTER WARNINGThe internal filters are almost dirty. Order new filters now.
FAN 12 ERRORFault in the extract air fan.
FAN 22 ERRORFault in the supply air fan.
BYPASS MOTOR 11 ERRORFault in the motor of the bypass damper on the return air side.
BYPASS MOTOR 20 ERRORFault in the motor of the bypass damper on the outdoor air side.
PRESSURE 12 ERRORFault in the pressure sensor for the extract air.
PRESSURE 22 ERRORFault in the pressure sensor for the supply air.
RV SENSOR 11 ERRORFault in the humidity sensor for the return air.
RV SENSOR 12 ERRORFault in the humidity sensor for the extract air.
RV SENSOR 20 ERRORFault in the humidity sensor for the outdoor air.
RV SENSOR 22 ERRORFault in the humidity sensor for the supply air.
TEMPSENSOR 11 ERRORFault in the temperature sensor for the return air.
TEMPSENSOR 12 ERRORFault in the temperature sensor for the extract air.
TEMPSENSOR 20 ERRORFault in the temperature sensor for the outdoor air, before the preheater.
TEMPSENSOR 21 ERRORFault in the temperature sensor for the outdoor air, after the preheater.
TEMPSENSOR 22 ERRORFault in the temperature sensor for the supply air.
VOORVERW.ERRORThe preheater does not heat enough.
VOORVERW.TE HEETThe preheater gets too hot.
VOORVERW.LOC.ERRORThe preheater is not in the right place, is faulty or is missing.

This is how to recognise and handle a fault:

  • A red warning symbol with "error" on the screen is a fault.
  • An orange symbol with "FILTERS VERVANGEN" (replace filters) is a filter message. Replace the filters and reset the filter timer in the "filter" menu.

For any other fault:

  1. Hold the screen for about 4 seconds until the child lock symbol disappears.
  2. Tap MENU and then the symbol above "errors".
  3. Tap the reset icon. The unit clears all error codes.
  4. If the message comes back, open "errors" again and write down all codes. Use the down arrow to see the next one.
  5. Write down the type from the rating plate.

Send the codes and type via WhatsApp, so we know what is needed. Do not pull the plug from the socket, as that can cause moisture and mould problems.

Source: Zehnder ComfoAir E 300 and E 400 user manual, Faults chapter.

Zehnder WHR 90, 91, 920, 930, 950 and 960
CodeMeaning
A0Temperature sensor for the outdoor air (ground heat exchanger) is faulty.
A1Sensor T1 (outdoor air) is faulty.
A2Sensor T2 (supply air) is faulty.
A3Sensor for the return air (T3) is faulty.
A4Sensor for the exhaust air (T4) is faulty.
A5, EA1, EA2A parameter has been set that does not belong to the unit. A technician has to check the settings.
A6Fault in the servo motor (bypass damper).
A7The anti-frost element does not heat enough.
A8The preheater gets too hot.
A10Sensor of the cooker hood (Tch) is faulty.
A11Sensor of the post-heater (Tah) is faulty.
BNABypass Not Available: the bypass cannot work.
E1The extract fan is not running.
E2The supply fan is not running.
E1 and E2 togetherBoth fans have stopped. Check the power first.
E3The exhaust air sensor is faulty (WHR 90/91 only).
F1Not enough airflow for the boiler (CombiFlow, WHR 930).
T3Not a fault. The unit is temporarily on setting 3 because a timer is running.
FIL or tErNot a fault. The filters need replacing.

Not every code occurs on every type. Zehnder Netherlands has an explanation per code and type. See the Zehnder fault pages. Most sensor and fan faults need a technician.

Does the code come back, or is your brand not listed?

Then the technician finds the cause on site, from € 149 including call-out and the first hour.

To the breakdown service

Book

Choose a day yourself

You book right here on the page. No form and no waiting for a phone call: you immediately see which days are free.

  • You see the price before you book
  • Rescheduling is possible up to 24 hours in advance
  • You get a text message the day before
  • Not satisfied with our work? Report it within 14 days and we will come back free of charge
“… fantastic service, good-quality materials and extremely pleasant, friendly communication.”
Marco · November 2026 · via Google